3M™ Attest™ Super Rapid Steam Biological Indicator Challenge Pack with Type 5 CI, 41482

2 Products Available

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

3M™ Attest™ Super Rapid Steam Biological Indicator Challenge Pack with Type 5 CI, 41482
(1) Super Rapid Readout Steam Challenge Pack
(2) BI results in just 24 minutes
(3) FDA-cleared pack and ISO-compliant components
(6) Presents a challenge equivalent to the 16-towel PCD recommended by AAMI
(6) Presents a challenge equivalent to the 16-towel PCD recommended by AAMI
(1) Super Rapid Readout Steam Challenge Pack
(5) For use with 3M Attest Auto-readers 490 & 490M
(4) Monitors 270F/132C 4min & 275F/135C 3min dynamic-air-removal steam sterilization cycles

About the product

The 3M™ Attest™ Super Rapid Readout Steam Biological Indicator Challenge Pack with Type 5 CI 41482V/41482VF, is a pre-assembled, white-wrapped test pack designed to monitor 270°F/132°C 4-minute and 275°F/135°C 3-minute dynamic-air-removal saturated steam sterilization cycles. Each pack includes a 3M™ Attest™ Steam Chemical Integrator, Type 5 and a 3M™ Attest™ Super Rapid Readout Steam Biological Indicator, 1492V, Brown Cap, 24 minute.

Product Options

1-2 of 2 Products

Select Filters to narrow your product list

Product name and IDs 3M ID Cap Color Incubation Period Brand

3M ID

7100208296

Cap Color

Brown

Incubation Period

24.0000 MINUTE

Brand

Attest™

3M ID

7100208295

Cap Color

Brown

Incubation Period

24.0000 MINUTE

Brand

Attest™

Product Details

The 3M™ Attest™ Super Rapid Readout Steam Biological Indicator Challenge Pack with Type 5 CI 41482V/41482VF comes pre-assembled in a white wrap and includes a 3M™ Attest™ Chemical Integrator, Type 5, one 3M™ Attest™ Super Rapid Biological Indicator 1492V, Brown Cap, 24 minute, a record-keeping sheet and a chemical process indicator on the pack label for convenience and ease of use. The challenge pack is FDA-cleared, and both the biological indicator (BI) and chemical integrator (CI) included are ISO-compliant. The BI must be used with the 3M™ Attest™ Auto-reader 490 or 490M.

This convenient, disposable challenge pack is specifically designed for rapid and reliable qualification testing and routine monitoring of 270°F/132°C 4-minute and 275°F/135°C 3-minute dynamic‑air‑removal (pre‑vacuum and steam‑flush pressure‑pulse (SFPP)) saturated steam sterilization cycles in healthcare facilities. The pack presents a challenge to the sterilization process equivalent to the user-assembled biological indicator (BI) challenge test pack (16-towel PCD) recommended by the Association for the Advancement of Medical Instrumentation (AAMI).

Reference the instructions for use for the applicable cycles in the U.S.

  • Pre-assembled, easy-to-use steam challenge pack includes a 3M™ Attest™ Steam Chemical Integrator, Type 5, and a 3M™ Attest™ Super Rapid Readout Steam Biological Indicator 1492V, Brown Cap, 24 minute
  • BI results in just 24 minutes
  • Monitors 270°F/132°C to 275°F/135°C dynamic-air-removal steam sterilization cycles
  • Presents a challenge to the steam sterilization process equivalent to the user-assembled BI challenge test pack (16-towel PCD) recommended by AAMI
  • FDA-cleared pack and ISO-compliant components
  • UDI-compliant 2-D barcode technology to capture BI GTIN, use-by date and lot code with handheld scanner
  • BI compatible with the 3M™ Attest™ Auto-reader 490 or 490M

Product Specifications

Brand
Brand

Attest™

Cap Color
Cap Color

Brown

Incubation Period
Incubation Period

24.0000

Sterilization

Contact a Solventum representative