Skip to main content

Mounting Kit for use with 3M™ Liqui-Cel™ Membrane Contactors

6 Products Available

Hover over image to zoom

Asset Main Image.

About the product

Mounting Kit for use with 3M™ Liqui-Cel™ Membrane Contactors includes the hardware, straps and cradles needed for convenient mounting of your 3M™ Liqui-Cel™ Membrane Contactor to a skid. Mounting kits are sold separately from the membrane contactor.

Product Options

1-5 of 6 Products

Select Filters to narrow your product list

Product name and IDs 3M ID Product Type Filter Technology Industries Product Series Brand

3M ID

7100175969

Product Type

Mounting Kit

Filter Technology

Membrane

Industries

Manufacturing

Product Series

EXF

Brand

Liqui-Cel™

3M ID

7100170101

Product Type

-

Filter Technology

Membrane

Industries

Manufacturing

Product Series

EXF

Brand

Liqui-Cel™

3M ID

7100170094

Product Type

-

Filter Technology

Membrane

Industries

Manufacturing

Product Series

EXF

Brand

Liqui-Cel™

3M ID

7100170080

Product Type

-

Filter Technology

Membrane

Industries

Manufacturing

Product Series

EXF

Brand

Liqui-Cel™

3M ID

7100170078

Product Type

-

Filter Technology

Membrane

Industries

Manufacturing

Product Series

EXF

Brand

Liqui-Cel™

3M ID

7100170077

Product Type

-

Filter Technology

Membrane

Industries

Manufacturing

Product Series

EXF

Brand

Liqui-Cel™

Product Details

Mounting Kit for use with 3M™ Liqui-Cel™ Membrane Contactors includes the hardware, straps and cradles needed for convenient mounting of your 3M™ Liqui-Cel™ Membrane Contactor to a skid. Mounting kits are sold separately from the membrane contactor.

Included in Mounting Kit
*For each of: EXF-14x28, EXF-14x40, EXF-8x40, EXF-8x80, EXF-8x20, EXF-6x28 and EXF-10x28 series membrane contactors in fiber reinforced plastic (FRP) housings:

  • Two rubber or two plastic cradles (depending on product)
  • Two steel t-bolt straps
  • Two PVC strap liners
*For EXF-10x28 series membrane contactors in compact-style stainless steel housings:

  • Two steel mounting brackets (clamps with bolt connections)


Note: Ensure that the right mounting is ordered for your membrane contactor. Please check with your 3M representative if you need assistance with mounting kit availability and selection.

About 3M™ Liqui-Cel™ Membrane Contactors
3M™ Liqui-Cel™ Membrane Contactors provide efficient dissolved gas control in a compact design. Capable of adding gases to or removing dissolved gases from compatible liquid streams, these gas transfer devices utilize hollow fiber membrane technology that may help facilities around the world improve operating efficiency, performance and protect product quality.

The presence of dissolved gases, such as oxygen, carbon dioxide, nitrogen and other non-condensable gases can cause a number of difficulties. Process interruptions, yield loss, corrosion, surface defects, unreliable measurement readings, poor product quality, higher operating costs and equipment inefficiency are a few examples of challenges faced by various industries when dissolved gases and air bubbles are not consistently controlled.

The 3M™ Liqui-Cel™ Membrane Contactor product offering includes products made with various materials of construction and a wide-range of flow capacities to meet process and application requirements. Their modular nature makes them easy to incorporate into systems with lower weight and less space than other conventional technologies, such as vacuum towers or forced draft deaerators. 3M™ Liqui-Cel™ Membrane Contactors do not require chemicals in operation and can be an effective alternative to chemical treatment options, such as oxygen scavengers in boiler feedwater or caustic/acid in reverse osmosis (RO) and other deionization systems. This may be particularly advantageous for facilities that want to reduce on-site chemical use as part of their sustainability goals.

How 3M™ Liqui-Cel™ Membrane Contactors Membrane Contactors Work
3M™ Liqui-Cel™ Membrane Contactors utilize microporous or non-porous, semi permeable hollow fiber membrane that is placed inside a contactor housing. In EXF, SP, and MM-0.5x1 and MM-0.75x1 series membrane contactors, liquid flows around the outside of the hollow fiber membrane while a vacuum and/or sweep gas is applied to the inside of the hollow fiber during operation. In other MM series membrane contactors liquid and gas flows are opposite: liquid flows inside of the hollow fiber membrane while a vacuum and/or sweep gas is applied to the outside of the hollow fiber.

Applying a vacuum or sweep gas creates a difference in the gas concentration levels between the inside (lumenside) and outside (shellside) of the hollow fiber membrane. This concentration difference is what drives rapid and efficient dissolved gas transfer.

  • Brackets help keep contactor in place on skids
  • Design permits easy access to installed membrane contactors
  • Convenient to have on hand during skid installation

Product Specifications

Industries
Industries

Manufacturing

Brand
Brand

Liqui-Cel™

Product Type
Product Type

Mounting Kit

Filter Technology
Filter Technology

Membrane

Product Series
Product Series

EXF

IF-PDP-XF

Ask an expert